| Section
1: Product and Company
Identification |
|
Product: |
CorrectDeck
& CorrectDeck CX |
|
Manufacturer: |
Correct
Building Products
8 Morin St.
Biddeford, ME 04005
Ph:207-284-5600
|
|
Preparation Date: |
May, 2000
|
|
Section
2: Composition, Information
on Ingredients
|
|
Component Name: |
CAS #, Composition
Amount
Wood Fiber(Sawdust): NA,
50-60%
Polypropylene: 9003-07-0,
40-50%
|
|
Section
3: Hazards Identification |
|
|
In normal use, the
product is not hazardous.
However, this product
may be cut or finished
in ways which produce
wood dust fibers. Certain
wood fibers are considered
hazardous if the airborne
concentration exceeds
the OSHA or ACGIH exposure
limits for long periods
of time. Exposure to such
fibers is considered unlikely
with this product; all
sawdust in the board is
fully stabilized in the
plastic resin matrix.
|
|
Section
4: Emergency and First
Aid Procedures |
|
Inhalation: |
This material is not
expected to present an
inhalation hazard. |
|
Eyes: |
Flush sawdust or fines
from eyes with water;
if irritation occurs,
obtain medical attention.
|
|
Skin: |
This material is not
expected to present a
skin contact hazard. |
|
Ingestion: |
No adverse affects
expected from ingestion.
|
Section
5: Fire and Explosion
Data |
|
Flash Point: |
Greater than 650F. |
| Upper
Explosive Limit: |
Not Determined |
| Lower
Explosive Limit: |
Not Determined |
| Auto
Ignition Temperature: |
Estimated to be greater
than 650F. |
| Extinguishing
Media: |
Dry Chemical, Water
Fog, Foam, Carbon Dioxide.
Special Fire Fighting
Procedures: Dense smoke
emitted when burned without
sufficient oxygen.
Possible dust explosion
if fines accumulate. Wear
standard fire fighting
attire (as for fighting
a wood fire), including
SCBA gear in enclosed
areas.
NEPA Hazard ID: Health:0
Flammability:1 Reactivity:0
|
Section
6: Spills and Disposal
Notification Procedures |
| Land
Spill: |
Material should be
swept up and discarded.
|
| Water
Spill: |
Clean up and discard
or reuse. |
| Waste
Disposal: |
Dispose of in accordance
with local regulations.
No special procedures
required.
|
Section
7: Handling and Storage
Handling |
|
|
CorrectDeck is heavier
than normal wood. Lift
carefully.
Storage: Support every
two feet on a flat surface.
Store away from strong
oxidizing agents or combustible
materials.
|
|
Section
8: Protective Measures |
| Ventilation: |
Use in well ventilated
area. |
| Respiratory
Protection: |
An approved respirator
may be needed in areas
with a high accumulation
of fines. |
| Eye
protection: |
Wear safety glasses
with side shields when
sawing or installing.
|
| Skin
protection: |
No special precautions
needed.
|
Section
9: Physical Data Appearance
and Odor |
|
Slight hardwood odor. |
|
Boiling Point: |
NA
|
|
Solubility in
Water: |
Insoluble
|
|
Vapor Pressure: |
Negligible
|
|
Melting Point: |
285-330F
|
|
Vapor Density: |
NA |
|
Percent Volatile: |
Negligible
|
Section
10: Reactivity Stability |
|
This
material is stable. |
| Conditions
to Avoid: |
Heat and flame
|
| Materials
to Avoid: |
Strong oxidizing agents
|
| Combustion
Products: |
Hazardous Polymerization:
Will not occur. |
| The
following combustion products
may be generated: |
carbon dioxide, carbon
monoxide, water vapor,
trace VOC's, Formic Acid,
Acetic Acid.
|
Section
11: Toxicological Data |
|
|
Exposure Limit of
Material Not established
LD50 of Material Not established
Carcinogenity of Material
None (wood dusts are fully
stabilized in the polymer
matrix)
|
Section
12: Ecological Considerations |
|
|
This material has
not been tested for environmental
effects.
|
|
Section
13: Disposal Considerations |
|
|
Dispose of as normal
refuse.
|
|
Section
14: Transport Information: |
|
This material is not
regulated by DOT. |
|
|
NEPA Hazard ID: Health:0
Flammability: 1 Reactivity:
0
|
|
Section
15: Regulatory Information |
|
|
WHMIS
Classification: This is
not a controlled product.
This material is not hazardous
by OSHA Hazardous Communication
Standard 29 CFR 1910.1200.
This material is not subject
to specific CERCLA, California
Safe Drinking Water and
Toxic Enforcement Act
(Proposition 65) or SARA
313 reporting requirements.
To the
best of our knowledge
the information contained
in this Material Safety
Data Sheet is accurate.
However, neither Correct
Building Products, LLC
nor any of its affiliates
makes any warranty, express
or implied, or accepts
any liability in connection
with this information